The fuel accumulator helps K-Jetronic systems hold residual pressure after shutoff so hot starts stay civilized. Diaphragm failure shows up as hot-start pain.

Related: K-Jetronic, hot start, fuel pump.
Function and symptoms
Helps residual pressure after pumps stop. Long hot cranks, easier cold starts, possible fuel odor at the unit, residual pressure falling too fast on a gauge.
Testing and replacement
CIS gauge against spec; isolate accumulator vs injector leak-down vs other paths. Replace correct unit, renew brittle hoses, recheck residual pressure and heat-soak restart.
Common mistakes
Skipping a cold and hot test drive, trusting verbal history without invoices, replacing parts before measuring, and ignoring rust while chasing mechanical gremlins. Another classic mistake is using photos from a different market or year as if they were a parts catalog.
When to stop DIY
Stop when you lack the gauge, puller, or safe support the job needs — or when the first repair did not change the symptom. A second identical guess rarely helps. Pay for diagnosis with a specialist who sees R107s regularly.
Practical takeaway
Measure with a CIS / K-Jetronic fuel pressure tester before parts-cannon weekends.
As an Amazon Associate I earn from qualifying purchases.
Verify procedures against the factory manual for your engine and chassis. I do not invent details about a specific personal car here — use your plates, your invoices, and your measured symptoms.
Shop notes and paperwork
Keep invoices, pressure readings, part numbers, and dated photos of the area before and after work. The next owner — or future you — will ask what was actually done. Verbal “we took care of it” evaporates at sale time.
Safety and scope
Use jack stands on solid ground, relieve fuel/coolant pressure before opening systems, and disconnect the battery when the procedure calls for it. If a step needs a specialty tool you do not own, rent it or hire it — improvising with the wrong lever is how fasteners and fingers break.
If this topic intersects fuel, rust, or safety systems, fix the safety and leak paths before cosmetic or convenience items. That order saves money twice.